BS-30A
Non-invasive ventilator
Comprehensive functions and excellent performance, suitable for clinical treatment and nursing
The elegant shape design, 5.7-inch large LCD screen and 17 ° tilt design combine excellent design ideas with high-quality treatment experience. Five ventilation modes and VAT volume guarantee technology provide comprehensive and efficient treatment support for patients.
Spare BS-30A non-invasive ventilator
National Health and Family Planning Commission outstanding domestic medical equipment
Safe, comfortable, easy to use and effective
Treatment function & use environment
4 major ventilation modes
CPAP mode (continuous positive pressure ventilation mode)
S mode (autonomous mode)
T mode (machine control mode)
S / T mode (autonomous / time control)
Application Environment
ICU, cardiology, neurology, respiratory, emergency, geriatric
Integrated trolley
The trolley can be equipped with a ventilator, a humidifier, a boom, a pipeline and a mask at the same time, and can move the entire treatment equipment with one hand.
Spare ST-30C parameters
Parameter | description |
Screen size | 5.7 inches color screen |
Waveform | flow, pressure dual waveform display |
Positive Inspiratory Pressure (IPAP) | 4cmH2O-30cmH2O |
Positive expiratory pressure (EPAP) | 4cmH2O-25cmH2O (not greater than positive inspiratory pressure) |
Continuous positive pressure (CPAP) | 4cmH2O-20cmH2O |
Climbing time | 0min-60min (one unit per minute) |
Climbing pressure in | CPAP mode: 4cmH2O-CPAP in other modes: 4cmH2O-EPAP |
Step-up gear (pressure rise time) | 1-6 |
Tidal volume range | 20ml-2500ml |
Inspiratory time | 0.2s ~ 4.0s |
Reserve breathing frequency | 1BPM ~ 60BPM |
Backup breathing frequency | apnea alarm, patient disconnection alarm, low minute ventilation alarm, low tidal volume alarm, power failure alarm, high voltage protection |
Real-time monitoring of data | pressure value, flow rate, minute ventilation, current tidal volume, minute respiratory rate, current leakage volume |
Other settings: | screen lock, screen brightness, flow scale, pressure scale, waveform mode |
Humidifier parameter | |
Heating temperature | 40 °-70 ° |
Adjustment unit | 1-9 |
Comprehensive safety protection, doctors are more at ease
Spare Medical’s non-invasive ventilator series, equipped with high-quality imported turbines, accurate and stable pressure; rich and comprehensive monitoring data, more conducive to the operation of medical staff, independent humidification system and 5 kinds of alarm reminders, making treatment safer and more comfortable
Rich monitoring data
Flow rate (waveform), pressure (waveform), minute ventilation, current tidal volume, minute respiratory rate, current leakage
Various alarm settings
Apnea alarm, disconnected alarm, low minute ventilation alarm, low tidal volume alarm, power failure alarm, high voltage protection
High quality imported turbine
High-quality imported turbine provides stable ventilation pressure and automatic leakage compensation to provide accurate and stable pressure, more at ease!
Independent professional humidifier
Professional humidification effect, the temperature can be adjusted from 1 to 9 gears, which greatly improves the effectiveness and comfort of treatment. Independent humidifier, to prevent backflow of water flow, damage the host to reduce the failure rate.
Effectively
innovate technology to achieve healthy breathing
The self-developed COMF pressure relief technology, AST automatic synchronization technology, VAT capacity guarantee technology, intelligent solenoid valve technology, four major innovations have achieved the excellent quality of Spira Medical non-invasive ventilator products, healthy breathing and natural comfort.
AST automatic synchronization technology
AST automatic synchronization technology can automatically monitor every breath of the patient, and respond to every breath of the patient in time through a variety of automatic triggering and withdrawal mechanisms such as flow rate, pressure, graphics, etc. to achieve perfect synchronization between the ventilator and the patient.
Automatic sensitivity technology, no need to manually set the sensitivity, minimize patient work, while improving clinical efficiency
With 60L / min automatic leakage compensation capability, it can also ensure the accuracy of synchronization and the stability of pressure in the case of a large amount of leakage, thereby improving the treatment effect.
COMF pressure relief technology
In the autonomous mode (S mode), the pressure is automatically released at the key point of the end of expiration of the breathing cycle according to the airflow, which makes the breathing process more comfortable, closer to natural physiological breathing, and brings more perfect comfort to the patient.
VAT capacity guarantee technology
The VAT capacity assurance technology automatically estimates the pressure required to reach the target tidal volume by monitoring the changes in the patient’s tidal volume, and provides progressive IPAP pressure control to automatically ensure the patient’s tidal volume. VAT capacity guarantee technology can meet more clinical needs and ensure the treatment effect.
Intelligent solenoid valve technology
Pressure rises up to the millisecond level, corresponding to each breath of the patient faster
Accurate pressure control to achieve better man-machine synchronization and treatment effect
Easy to use and
good design, treatment becomes simple
5.7-inch large color screen:
display dual waveforms, parameter settings, real-time treatment and other data on the same screen,
without turning the screen.
Full Chinese interface & dual waveform display:
easy to read, easy to read parameters at the same time, and analyze the condition
Multi-function rotary button design:
simpler operation, improve the utilization rate of department equipment.
Human-centered product design:
more convenient viewing angle, improve clinical efficiency and level
Some precautions for using ventilator?
The patient should pay attention to the following points when using the ventilator for the first time :
a. When using the ventilator for the first time, first turn it on and off once to determine whether the switch can be properly controlled and check whether the machine is working properly. If you have any questions, please contact the seller or manufacturer in time.
b. Read the product manual carefully before use, and connect the ventilator, humidifier, nasal mask or mouth-nose mask according to the instructions in the manual.
c. Wear the nasal mask or mouth-nose mask and adjust the headband tightness. The elasticity of the headband is generally suitable if the mask does not have a pressure on the patient’s corresponding parts, but it should not be too loose to avoid air leakage.
d. Make sure that the humidifier has been added with purified water or distilled water, and can not exceed the specified position.
e. Start the ventilator and feel if there is any abnormality in the operation of the ventilator. If there is no abnormality, you can use it with confidence.
f. If the patient wants to temporarily leave the machine during use, it is best to turn off the machine, take off the nasal mask or mouth and nose mask, and then leave. After returning, wear the nasal mask or mouth and nose mask before restarting.
g. After using every day, be sure to turn off the machine and then cut off the power.
h. It is best to clean the mask once a day, and filter sheets and pipes every three days. The cleaning method can refer to the disinfection method of ventilator accessories.
i. Change the water in the humidifier every day, preferably not exceeding the water level line.
j. The machine should be maintained every six months or a year. You can contact the sales company or manufacturer when maintenance is required.