BS-NC Series
High-flow non-invasive respiratory humidification treatment instrument
Oxygen concentration precise control technology, intelligent temperature and humidity control system, 70L / min high flow output
The high-flow non-invasive respiratory humidification treatment instrument is used for patients with spontaneous breathing, which provides effective treatment by providing a certain flow rate and heating and humidifying breathing gas. These patients include patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy. Cannot be used for life support equipment.
Spree BS-NC Series
High-flow non-invasive respiratory humidification treatment instrument
Oxygen concentration precise control technology / Intelligent temperature and humidity control system / 70L / min high flow output
Spare BS-NC Series high-flow non-invasive breathing humidification therapy instrument provides effective breathing treatment for patients by providing high flow, accurate oxygen concentration and warming and humidifying air-oxygen mixed gas.
Spirax BS-NC Series
can quickly improve patients’ oxygenation level and maintain the normal operation of airway mucus cilia. It is mainly suitable for patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy.
Applicable department
Respiratory, ICU, Emergency Department, Neurology, Neurosurgery, Geriatrics, Cardiothoracic Surgery, Cardiology, Pediatrics
Characteristics of high-flow non-invasive respiratory humidification treatment
Provide stable high oxygen absorption concentration, improve blood oxygen quickly and effectively
Scour physiological anatomical dead spaces and reduce carbon dioxide re-inhalation
Form a certain positive airway pressure to keep the airway open
With sufficient humidification and warming, the airway mucus cilia cleaning function is at its best.
Comfortable user experience and improved compliance.
Spare BS-NC Series
parameters
model | OH-70C | OH-70B | OH-60A |
mode | High flow mode Low flow mode | ||
Precise adjustment of oxygen concentration | Precise control | manual adjustment | |
Oxygen concentration software settings | 21% —100% (1% adjustment accuracy) | —— | |
Flow setting | 2L / min-70 L / min | 2L / min-70 L / min | 2L / min-60 L / min |
Temperature setting | 31 ℃ -37 ℃ / seven adjustable | 31 ℃, 34 ℃, 37 ℃ | 31 ℃, 34 ℃, 37 ℃ |
Timing function | Have | —— | |
Trend review | 1 day, 3 day, 7 day temperature and humidity, oxygen concentration, flow review waveform | ||
Patient interface | Nasal congestion interface, tube cutting interface, mask | ||
Real-time monitoring parameters | Flow rate, temperature, oxygen concentration | ||
Alarm prompt | Pipeline alarm, oxygen pressure alarm, clogging alarm, temperature alarm, power failure alarm, low ambient temperature reminder, oxygen concentration not reaching the preset value, flow rate not reaching the preset value, preset time remind |
effective
Oxygen concentration precise control technology
High-precision proportional valve controls oxygen concentration, no external manual adjustment is required, and oxygen concentration control is more precise
21% -100% oxygen concentration adjustment range, 1% oxygen concentration adjustment accuracy
When the flow rate changes, the proportional valve of the air-oxygen mixer is adjusted according to the software setting to ensure a constant oxygen concentration
Built-in accurate oxygen concentration monitoring module can realize the accurate display of oxygen concentration index without loading consumables such as oxygen battery
Intelligent temperature and humidity control system
It can provide gas close to the core temperature of the human body (37 ℃) and 100% relative humidity (44mg / L), so that the mucus cilia cleaning function is in the best state
Temperature control: 31 ℃ -37 ℃, adjustable in seven gears
Adjust heating and humidification system to ensure accurate and constant temperature and humidity
70L / min high flow rate to meet more clinical needs
2-70L / min flow adjustment range to meet more clinical needs
Can effectively wash away the physiological anatomical dead space and prevent carbon dioxide re-inhalation
Built-in multi-point flow sensor to ensure accurate and stable flow
Comfortable
- Fully humidified gas and suitable temperature
Bring a comfortable treatment experience to patients
- Imported special silicone stuffy nose
No pressure, patients are well tolerated and highly compliant
- Intelligent temperature and humidity control system
Ensure the gas temperature and humidification effect at the patient end, improve patient comfort and prevent condensation
- Provides four different patient interfaces
Suitable for different people and meet clinical needs
Safe & easy to use
- Innovative safe airway design without disinfection inside
Using a unique safety design, patient gas does not return to the host, the machine does not need to be disinfected, to prevent cross infection
- Original trend review function, full control of the patient’s situation
It can review the data of temperature, humidity, flow rate and oxygen concentration in 1-7 days to fully control the patient’s situation
- Disposable heating water box and heating pipeline
One-time consumables, no need for disinfection,
water tank to prevent cross-infection can be added automatically, without manual operation
- 4.3-inch large color screen & multi-function knob design
Multiple treatment data can be set and monitored, the operation is more convenient, and the clinical efficiency is improved
- Integrated trolley & boom
It is convenient for bed treatment and movement in the department, and can be operated with one hand
Product registration certificate number: Xiang Machinery Note 20172540225
Please refer to the instruction manual for the clinical application scope of the high-flow non-invasive respiratory humidification treatment instrument
Some precautions for using ventilator?
The patient should pay attention to the following points when using the ventilator for the first time :
a. When using the ventilator for the first time, first turn it on and off once to determine whether the switch can be properly controlled and check whether the machine is working properly. If you have any questions, please contact the seller or manufacturer in time.
b. Read the product manual carefully before use, and connect the ventilator, humidifier, nasal mask or mouth-nose mask according to the instructions in the manual.
c. Wear the nasal mask or mouth-nose mask and adjust the headband tightness. The elasticity of the headband is generally suitable if the mask does not have a pressure on the patient’s corresponding parts, but it should not be too loose to avoid air leakage.
d. Make sure that the humidifier has been added with purified water or distilled water, and can not exceed the specified position.
e. Start the ventilator and feel if there is any abnormality in the operation of the ventilator. If there is no abnormality, you can use it with confidence.
f. If the patient wants to temporarily leave the machine during use, it is best to turn off the machine, take off the nasal mask or mouth and nose mask, and then leave. After returning, wear the nasal mask or mouth and nose mask before restarting.
g. After using every day, be sure to turn off the machine and then cut off the power.
h. It is best to clean the mask once a day, and filter sheets and pipes every three days. The cleaning method can refer to the disinfection method of ventilator accessories.
i. Change the water in the humidifier every day, preferably not exceeding the water level line.
j. The machine should be maintained every six months or a year. You can contact the sales company or manufacturer when maintenance is required.