BS-NC Series

High-flow non-invasive respiratory humidification treatment instrument

Oxygen concentration precise control technology, intelligent temperature and humidity control system, 70L / min high flow output

The high-flow non-invasive respiratory humidification treatment instrument is used for patients with spontaneous breathing, which provides effective treatment by providing a certain flow rate and heating and humidifying breathing gas. These patients include patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy. Cannot be used for life support equipment.

 

Spree BS-NC Series

High-flow non-invasive respiratory humidification treatment instrument

Oxygen concentration precise control technology / Intelligent temperature and humidity control system / 70L / min high flow output

Spare BS-NC Series high-flow non-invasive breathing humidification therapy instrument provides effective breathing treatment for patients by providing high flow, accurate oxygen concentration and warming and humidifying air-oxygen mixed gas.

Spirax BS-NC Series
can quickly improve patients’ oxygenation level and maintain the normal operation of airway mucus cilia. It is mainly suitable for patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy.

Applicable department

Respiratory, ICU, Emergency Department, Neurology, Neurosurgery, Geriatrics, Cardiothoracic Surgery, Cardiology, Pediatrics

Characteristics of high-flow non-invasive respiratory humidification treatment

Provide stable high oxygen absorption concentration, improve blood oxygen quickly and effectively

Scour physiological anatomical dead spaces and reduce carbon dioxide re-inhalation

Form a certain positive airway pressure to keep the airway open

With sufficient humidification and warming, the airway mucus cilia cleaning function is at its best.

Comfortable user experience and improved compliance.

Spare BS-NC Series
parameters
modelOH-70COH-70BOH-60A
modeHigh flow mode Low flow mode
Precise adjustment of oxygen concentrationPrecise controlmanual adjustment
Oxygen concentration software settings21% —100% (1% adjustment accuracy)——
Flow setting2L / min-70 L / min2L / min-70 L / min2L / min-60 L / min
Temperature setting31 ℃ -37 ℃ / seven adjustable31 ℃, 34 ℃, 37 ℃31 ℃, 34 ℃, 37 ℃
Timing functionHave——
Trend review1 day, 3 day, 7 day temperature and humidity, oxygen concentration, flow review waveform
Patient interfaceNasal congestion interface, tube cutting interface, mask
Real-time monitoring parametersFlow rate, temperature, oxygen concentration
Alarm promptPipeline alarm, oxygen pressure alarm, clogging alarm, temperature alarm, power failure alarm, low ambient temperature reminder, oxygen concentration not reaching the preset value, flow rate not reaching the preset value, preset time remind
 
effective

Oxygen concentration precise control technology

High-precision proportional valve controls oxygen concentration, no external manual adjustment is required, and oxygen concentration control is more precise

21% -100% oxygen concentration adjustment range, 1% oxygen concentration adjustment accuracy

When the flow rate changes, the proportional valve of the air-oxygen mixer is adjusted according to the software setting to ensure a constant oxygen concentration

Built-in accurate oxygen concentration monitoring module can realize the accurate display of oxygen concentration index without loading consumables such as oxygen battery

Intelligent temperature and humidity control system

It can provide gas close to the core temperature of the human body (37 ℃) and 100% relative humidity (44mg / L), so that the mucus cilia cleaning function is in the best state

Temperature control: 31 ℃ -37 ℃, adjustable in seven gears

Adjust heating and humidification system to ensure accurate and constant temperature and humidity

70L / min high flow rate to meet more clinical needs

2-70L / min flow adjustment range to meet more clinical needs

Can effectively wash away the physiological anatomical dead space and prevent carbon dioxide re-inhalation

Built-in multi-point flow sensor to ensure accurate and stable flow

Comfortable

Fully humidified gas and suitable temperature

Bring a comfortable treatment experience to patients

Imported special silicone stuffy nose

No pressure, patients are well tolerated and highly compliant

Intelligent temperature and humidity control system

Ensure the gas temperature and humidification effect at the patient end, improve patient comfort and prevent condensation

Provides four different patient interfaces

Suitable for different people and meet clinical needs

Safe & easy to use

Innovative safe airway design without disinfection inside

Using a unique safety design, patient gas does not return to the host, the machine does not need to be disinfected, to prevent cross infection

Original trend review function, full control of the patient’s situation

It can review the data of temperature, humidity, flow rate and oxygen concentration in 1-7 days to fully control the patient’s situation

Disposable heating water box and heating pipeline

One-time consumables, no need for disinfection,
water tank to prevent cross-infection can be added automatically, without manual operation

4.3-inch large color screen & multi-function knob design

Multiple treatment data can be set and monitored, the operation is more convenient, and the clinical efficiency is improved

Integrated trolley & boom

It is convenient for bed treatment and movement in the department, and can be operated with one hand

Product registration certificate number: Xiang Machinery Note 20172540225

Please refer to the instruction manual for the clinical application scope of the high-flow non-invasive respiratory humidification treatment instrument

Some precautions for using ventilator?

The patient should pay attention to the following points when using the ventilator for the first time :

a. When using the ventilator for the first time, first turn it on and off once to determine whether the switch can be properly controlled and check whether the machine is working properly. If you have any questions, please contact the seller or manufacturer in time.

b. Read the product manual carefully before use, and connect the ventilator, humidifier, nasal mask or mouth-nose mask according to the instructions in the manual.

c. Wear the nasal mask or mouth-nose mask and adjust the headband tightness. The elasticity of the headband is generally suitable if the mask does not have a pressure on the patient’s corresponding parts, but it should not be too loose to avoid air leakage.

d. Make sure that the humidifier has been added with purified water or distilled water, and can not exceed the specified position.

e. Start the ventilator and feel if there is any abnormality in the operation of the ventilator. If there is no abnormality, you can use it with confidence.

f. If the patient wants to temporarily leave the machine during use, it is best to turn off the machine, take off the nasal mask or mouth and nose mask, and then leave. After returning, wear the nasal mask or mouth and nose mask before restarting.

g. After using every day, be sure to turn off the machine and then cut off the power.

h. It is best to clean the mask once a day, and filter sheets and pipes every three days. The cleaning method can refer to the disinfection method of ventilator accessories.

i. Change the water in the humidifier every day, preferably not exceeding the water level line.

j. The machine should be maintained every six months or a year. You can contact the sales company or manufacturer when maintenance is required.