BS-NC1

High-flow non-invasive respiratory humidification treatment instrument

Medical grade product performance parameters Intelligent temperature and humidity control system effectively improves blood oxygen saturation, better airway humidification and protection

The high-flow non-invasive breathing humidification treatment instrument is used for patients with spontaneous breathing, which provides effective treatment by providing a certain flow rate and heating and humidifying breathing gas. These patients include patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy. Cannot be used for life support equipment.

Spree BS-NC1

High-flow non-invasive respiratory humidification treatment instrument

– Performance parameters of medical grade products
– Intelligent temperature and humidity control system
– Effectively improve blood oxygen saturation
– Better airway humidification and protection

The high-flow non-invasive breathing humidification treatment instrument is used for patients with spontaneous breathing, which provides effective treatment by providing a certain flow rate and heating and humidifying breathing gas. These patients include patients with humidification therapy, oxygen therapy, endotracheal intubation and tracheotomy. Cannot be used for life support equipment.

Spare OH series parameters
modelBS-NC1
Flow setting2L / min-60 L / min
Temperature setting31 ℃, 34 ℃, 37 ℃
Oxygen concentration monitoring functionHave
Trend review1 day, 3 day, 7 day temperature and humidity, oxygen concentration, flow review waveform
User InterfaceStuffy interface, cutting tube interface
Real-time monitoring parametersFlow rate, temperature, oxygen concentration
Alarm promptPipeline alarm, blockage alarm, temperature alarm, power failure alarm, low ambient temperature reminder, flow rate not reaching pre-value reminder

Humidification

Intelligent temperature and humidity control system

– Protect the airway
– Helps sputum
– Prevent infection

Oxygen Therapy

Combine with home oxygen generator to provide more comfortable and effective oxygen therapy

– Protect the airway
– Helps sputum
– Prevent infection

Can provide the latest human core temperature (37 ℃) and 100% relative humidity (44mg / L)

The gas makes the mucus cilia cleaning function in the best state, which is helpful for sputum discharge and prevents infection

The temperature control can be adjusted in three levels: 31 ℃, 34 ℃, 37 ℃, to meet the needs of different users;

Ensure the temperature and humidification of the gas at the user end, improve user comfort, and prevent condensation.

2-60L / min high flow adjustment range to meet the needs of more users

Can effectively wash away the physiological anatomical dead space, prevent carbon dioxide re-inhalation, and effectively improve blood oxygen

Fully humidified gas and suitable temperature

Bring a comfortable treatment experience to patients

Imported special silicone stuffy nose

No pressure, good tolerance, high compliance

Provides four different patient interfaces

Suitable for different people and meet clinical needs

Safe airway design to prevent infection

The internal air passage of the machine adopts a unique safety design, the user’s airflow does not return to the host, and no sterilization is required.

Original trend review function, full control of the patient’s situation

It can review the data of temperature, humidity, flow rate and oxygen concentration in 1-7 days to fully control the patient

4.3-inch large color screen & multi-function knob design

Multiple treatment data can be set and monitored, the operation is more convenient, and the clinical efficiency is improved

Some precautions for using ventilator?

The patient should pay attention to the following points when using the ventilator for the first time :

a. When using the ventilator for the first time, first turn it on and off once to determine whether the switch can be properly controlled and check whether the machine is working properly. If you have any questions, please contact the seller or manufacturer in time.

b. Read the product manual carefully before use, and connect the ventilator, humidifier, nasal mask or mouth-nose mask according to the instructions in the manual.

c. Wear the nasal mask or mouth-nose mask and adjust the headband tightness. The elasticity of the headband is generally suitable if the mask does not have a pressure on the patient’s corresponding parts, but it should not be too loose to avoid air leakage.

d. Make sure that the humidifier has been added with purified water or distilled water, and can not exceed the specified position.

e. Start the ventilator and feel if there is any abnormality in the operation of the ventilator. If there is no abnormality, you can use it with confidence.

f. If the patient wants to temporarily leave the machine during use, it is best to turn off the machine, take off the nasal mask or mouth and nose mask, and then leave. After returning, wear the nasal mask or mouth and nose mask before restarting.

g. After using every day, be sure to turn off the machine and then cut off the power.

h. It is best to clean the mask once a day, and filter sheets and pipes every three days. The cleaning method can refer to the disinfection method of ventilator accessories.

i. Change the water in the humidifier every day, preferably not exceeding the water level line.

j. The machine should be maintained every six months or a year. You can contact the sales company or manufacturer when maintenance is required.